ABSTRACT
New platforms for the rapid and sensitive detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern are urgently needed. Here we report the development of a nanomechanical sensor based on the deflection of a microcantilever capable of detecting the SARS-CoV-2 spike (S) glycoprotein antigen using computationally designed multivalent minibinders immobilized on a microcantilever surface. The sensor exhibits rapid (<5 min) detection of the target antigens down to concentrations of 0.05 ng/mL (362 fM) and is more than an order of magnitude more sensitive than an antibody-based cantilever sensor. Validation of the sensor with clinical samples from 33 patients, including 9 patients infected with the Omicron (BA.1) variant observed detection of antigen from nasopharyngeal swabs with cycle threshold (Ct) values as high as 39, suggesting a limit of detection similar to that of the quantitative reverse transcription polymerase chain reaction (RT-qPCR). Our findings demonstrate the use of minibinders and nanomechanical sensors for the rapid and sensitive detection of SARS-CoV-2 and potentially other disease markers.
Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Clinical Laboratory Techniques , Humans , SARS-CoV-2/genetics , Sensitivity and SpecificityABSTRACT
The rapid spread of COVID-19 including recent emergence of new variants with its extreme range of pathologies create an urgent need to develop a versatile sensor for a rapid, precise, and highly sensitive detection of SARS-CoV-2. Herein, we report a microcantilever-based optical detection of SARS-CoV-2 antigenic proteins in just few minutes with high specificity by employing fluidic-atomic force microscopy (f-AFM) mediated nanomechanical deflection method. The corresponding antibodies against the target antigens were first grafted on the gold-coated microcantilever surface pre-functionalized with EDC-NHS chemistry for a suitable antibody-antigen interaction. Rapid detection of SARS-CoV-2 nucleocapsid (N) and spike (S1) receptor binding domain (RBD) proteins was first demonstrated at a clinically relevant concentration down to 1 ng/mL (33 pM) by real-time monitoring of nanomechanical signal induced by antibody-antigen interaction. More importantly, we further show high specific detection of antigens with nasopharyngeal swab specimens from patients pre-determined with qRT-PCR. The results take less than 5 min (swab to signal ≤5 min) and exhibit high selectivity and analytical sensitivity (LoD: 100 copies/ ml; 0.71 ng/ml of N protein). These findings demonstrate potential for nanomechanical signal transduction towards rapid antigen detection for early screening of SARS-CoV-2 and its related mutants.